Heating and cooling
Ventilation, ERVs and HRVs: bringing in fresh air without wasting the heat
A tighter house leaks less air, so the air you breathe has to come from somewhere on purpose. Heat and energy recovery ventilators bring it in and take back part of the heat or moisture on the way.
By VoltHearth Editorial Team Updated 7 min read
- HRV moves
- Heat only
- ERV moves
- Heat and moisture
- Typical heat recovery
- 55% to 95% (2014 guide)
- Federal credit (25C)
- Ended Dec. 31, 2025
At a glance
A heat recovery ventilator (HRV) and an energy recovery ventilator (ERV) are balanced systems: they exhaust stale air and supply outdoor air at the same time. An HRV transfers sensible heat only; an ERV also transfers moisture, according to a Department of Energy guide. The fans use electricity all year, so check the watts. A ventilator is a comfort and indoor air measure, not a big bill cutter, and the federal credit ended for 2026 work.
Why a home needs planned ventilation
Air sealing and insulation cut drafts, and drafts were once a home's ventilation. A Pacific Northwest National Laboratory checklist gives the main reason to ventilate on purpose as health: contaminants in homes can trigger asthma and allergy attacks as well as other health problems. Planned ventilation also adds comfort. If you are sealing the house, read air sealing and weatherstripping alongside this page.
Exhaust-only
Fans run continuously or on timers to remove air, and makeup air leaks in on its own. It is the simplest setup, and the incoming air is not filtered or tempered.
Central fan integrated supply
Uses the forced-air system's air handler and a motorized outdoor air damper. It only suits a home that already has forced-air heating or cooling.
Balanced (HRV or ERV)
Exhausts and supplies at the same time, and a core passes heat between the two streams. This is the type this page covers.
HRV or ERV
Both pass indoor and outdoor air streams through a core so the outgoing air warms or cools the incoming air. The DOE guide says HRVs transfer sensible heat only, while ERVs also transfer moisture. The question it poses is whether your typical indoor moisture level is more comfortable than the outdoor level. If it is, an ERV may be the more practical choice, because it holds back some of the moisture you want to keep in winter or keep out in a humid summer. Your climate and how you live decide it, so ask the installer to explain the choice for your area.
The same guide says the sensible effectiveness of ERV and HRV cores typically ranges from 55% to 95%. It is a February 2014 document, so use it for the idea rather than for current models, and compare the maker's current ratings.
How much air a home needs
The DOE guide cites the ASHRAE 62.2 formula. The 2013 version gives total ventilation in cubic feet per minute (cfm) as 0.03 times floor area in square feet, plus 7.5 times the number of bedrooms plus one. The fan's share is that total minus the home's effective infiltration. Later editions of the standard exist, so ask the installer which one your area uses.
- Floor area term. For a hypothetical 2,000-square-foot home, 0.03 × 2,000 = 60 cfm.
- Bedroom term. With three bedrooms, 7.5 × (3 + 1) = 30 cfm.
- Total. 60 + 30 = 90 cfm before any credit for leakage. A measured airflow at commissioning shows whether the installed unit delivers it.
What the fans cost to run
A ventilator's electricity is the watts of the fans times the hours they run, divided by 1,000. The DOE guide gives two examples: a 10-watt fan running all year, and a 300-watt air handler running 8 hours a day. At the 2025 U.S. average residential price of 17.23¢ per kWh (EIA), they work out as follows.
| Fan | Hours a year | kWh | Cost |
|---|---|---|---|
| 10 watts, all year | 8,760 | 87.6 | About $15 |
| 300 watts, 8 hours a day | 2,920 | 876 | About $151 |
The 300-watt case is why a central-fan design costs more to run than a small dedicated fan. Ask for the installed unit's watts at the airflow you need. The appliance running cost calculator runs the same sum with your own price.
Installation points to check
- Intake placement. PNNL says the exhaust outlet should be at least 10 feet from any air inlet, and the DOE guide keeps intakes at least 10 feet from contaminant sources.
- Dedicated ducts. If a unit ties into the central ductwork, the DOE guide recommends a dedicated duct run for at least one side. Exhaust ducts should end outdoors, never in an attic or crawlspace.
- Sealed ducts. Both sources call for mastic or approved foil tape on duct seams. See ductwork and airflow.
- Filter and access. PNNL says outdoor air should pass a MERV 11 filter or higher that occupants can reach easily. The DOE guide says filters and cores need regular cleaning or replacement.
- Commissioning. PNNL says airflow should be measured, with a flow hood, flow grid or anemometer, under the ANSI/RESNET/ICC 380-2016 method, and that the installer should review operation and maintenance with you. A unit that was never measured may not deliver the airflow it was sized for.
What to ask an installer
- How did you set the airflow target, and will you measure the delivered airflow at the end?
- HRV or ERV for my climate and why?
- What are the unit's fan watts at that airflow?
- Where are the intake and exhaust, and how far apart?
- How often does the filter need changing, and can I reach it?
Credits and rebates in 2026
The federal Energy Efficient Home Improvement Credit (25C) ended for property placed in service after December 31, 2025, so work finished in 2026 earns no federal credit. See what happened to 25C and 25D. DOE's rebate page lists ventilation among the upgrades its electric home rebate program can be used for, and says home energy rebates are available in select states. Contact your state energy office for status, then the rebate guide explains the programs.
Quick answers
What is the difference between an HRV and an ERV?
A DOE guide says HRVs transfer sensible heat only, and ERVs also transfer moisture. Both exhaust and supply air at the same time.
Do I need an ERV if my house is leaky?
A leaky house gets its air by accident. Sealing it makes the air supply a decision. Ask a professional to measure the leakage and set a ventilation target before you choose equipment.
How much does an ERV cost to run?
It depends on the fan watts and the hours. As an illustration, a 10-watt fan running all year uses 87.6 kWh, which is about $15 at 17.23¢ per kWh. Ask for your unit's watts at the airflow you need.
Is there a federal tax credit for ventilation equipment?
Not for work placed in service after December 31, 2025. The 25C credit ended on that date. Check state and utility programs.
Sources
- U.S. Department of Energy, Building America — Measure guideline: selecting ventilation systems for existing homes (February 2014)
- PNNL Building America Solution Center — Balanced HRV/ERV checklist
- IRS — Energy Efficient Home Improvement Credit
- U.S. Department of Energy — Home Energy Rebates
- EIA — Electricity data by state
Facts on this page were checked against these sources on November 19, 2026. The DOE ventilation guide is dated February 2014 and cites ASHRAE 62.2 editions from 2010 and 2013, so confirm the current edition and local code. The floor-area example is hypothetical, and the price is EIA's 2025 U.S. average.
Read next
-
Upgrade
Air sealing and weatherstripping
Where houses leak, which fix suits which gap, and how a blower door test checks the result.
-
Upgrade
Ductwork and airflow
What leaky ducts cost, the signs to look for and how sealing and insulating work.
-
Upgrade
Home energy audit
What an assessment includes, how to pick an auditor, and how to use the report to set the order of work.